Savol - Javob

Серия устройств
Модель устройства

G Series

G1, G2, G3, G3 Plus, G3-H, G4, G4L, G3 Pro

Horus Series

Horus TL1, Horus E1, Horus E1-RFID, Horus E1-FP

SpeedFace Series

SpeedFace V4L, SpeedFace V4L [TI], SpeedFace V5, SpeedFace V5L, SpeedFace V5L [TD], SpeedFace V5L [TI], SpeedFace H5, SpeedFace H5L, SpeedFace М1, SpeedFace М2, SpeedFace М3, SpeedFace М4

ProFaceX Series

ProFaceX, ProFaceX [P], ProFaceX [TD], ProFaceX [TI], ProFaceX [SL]

USB-считыватели

ZK4500, ZK8500R, ZK9500, SLK20R

Могут работать с BioTA 8.0 при наличии опции ADMS

C Series

A11-C, B3-C, S160-C, X628-C, X628-TC, U160-C, U260-C, U300-C, U560-C, U990-C

F Series

F22

iClock Series

iClock260, iClock360, iClock460, iClock480, iClock560, iClock580, iClock660, iClock660-3G, iClock680, iClock680-3G, iClock700, iClock880, iClock990

IN Series

IN01, IN01-A, IN02, IN02-A, IN03, IN04, IN05, IN05-A

KF Series

KF160, KF460

LP Series

LP400

MB Series

MB1000, MB2000, MB160, MB360, MB460, MB560-VL, MB10, MB20, MB30, MBP10

P Series

P160, P260

S Series

S500, S560, S880, S900, S922

Silk Series

SilkFP-101TA, SilkBio-100TC, SilkBio-101TC

UA Series

UA100, UA200, UA300, UA400, UA500, UA760, UA860

uFace Series

uFace202, uFace302, uFace402, uFace602, uFace800, PFace202, SFace900, uFace202 Plus, uFace302 Plus, uFace401 Plus, uFace402 Plus, uFace602 Plus, uFace800 Plus

VF Series

VF300, VF600, VF700, VF380, VF680, VF780

  • Версия службы push service должна быть не ниже Ver2.0.36-20190423
  • Контроллеры с BioTA 8.0 не работают.
  • Terminal AVR rejimida bo'lishi kerak.
    (Rejimni qurilma menyusida tekshirishingiz mumkin)
  • Terminal BioTA 8.0 dasturiy ta'minoti o'rnatilgan server bilan bir xil mahalliy tarmoqda IP manzilini olganligiga ishonch hosil qiling (terminallarda sukut bo'yicha IP 192.168.1.201 mavjud).
  • Terminalda, bulut xizmati sozlamalarida BioTA 8.0 dasturiy ta'minoti o'rnatilgan server manzilini, shuningdek ulanish portini (sukut bo'yicha 80) ko'rsatishingiz kerak.
  • Terminaldagi HTTPS rejimi faqat BioTA 8.0 ushbu protokoldan foydalansa faollashtirilishi kerak.
    (HTTPS qo'llab-quvvatlash server boshqaruv konsolida sozlangan)
  • Yuqoridagi amallarni bajarganingizdan so'ng, qurilma "Qurilmalar" sahifasida avtomatik ravishda paydo bo'lishi kerak. 

Qurilma standart zonada joylashgan boʻlib, unda maʼlumotlarni uzatish imkonsizdir. Alohida zonani yaratish kerak. Birlamchi nomini oʻzgartirish va undan kichiklarini yaratishning hojati yoʻq .

Har bir mobil ilova shaxsiy vaqtni kuzatish terminali vazifasini bajaradi va faol ilovalar soni litsenziya bilan cheklanadi. Shuning uchun, dastlab barcha xodimlar mobil ilovaga kirish imkoniyatidan mahrum. Bu dasturiy ta'minotning umumiy ishlashiga ta'sir qilmaydi.

Bu 80-portda Windows ISS xizmati tomonidan allaqachon band bo'lganligi sababli sodir bo'ladi. Yechim server konsolidagi portni 80 dan boshqasiga o'zgartirishdir. Portni almashtirishdan oldin barcha BioTA 8.0 xizmatlarini to'xtatishingiz kerak

Avvalo, siz smena tuzilgan ish kuni jadvalini belgilashingiz kerak. Keyin jadval tayinlanadi, bu ma'lum vaqt oralig'ida xodimga tayinlangan smenalardir. Shundan so'ng hisobotlarni yaratish uchun hisob-kitoblarni amalga oshirish kerak.

Hodisalar jadval sozlamalaridagi Kelish/Ketish oralig'iga to'g'ri kelmasa, bu sodir bo'lishi mumkin. Shuningdek, Shift sozlamalarini va Jadval hisob-kitob davriga tayinlanganligini tekshirishingiz kerak.

Agar siz terminaldan haroratni o'lchamasdan foydalansangiz, hisobot sozlamalarida "Harorat va niqobni hisobga olish" ni o'chirib qo'yishingiz kerak. va oʻzgarishlarni saqlang.

255 hodisa holati yo'q degan ma'noni anglatadi. Terminalning o'zi sozlamalarida mos keladigan menyu bandini faollashtirish kerak, chunki voqea holati terminal tomonidan tayinlanadi. Terminaldagi holatlar hisob-kitobga ta’sir qilmasligi uchun Jadval qoidalari sozlamalarida “Belgi holatini hisobga olish”ni o‘chirib qo‘yishingiz mumkin.

ZKTeco mahsulot liniyasining aksariyati: kontrollerlar, ACS rejimidagi terminallar (ADMS opsiyasi bilan), CCTV kameralari, LPR kameralari, videomagnitofonlar, FaceKiosk.

  • Terminal ACS rejimida bo'lishi kerak.
    (Rejimni qurilma menyusida tekshirishingiz mumkin) 
  • Terminal BioSecurity dasturi oʻrnatilgan server bilan bir xil mahalliy tarmoqda IP-manzil olganligiga ishonch hosil qiling (terminallarda sukut boʻyicha IP 192.168.1.201 mavjud). 
  • Terminalda, bulut xizmati sozlamalarida siz BioSecurity dasturi oʻrnatilgan server manzilini, shuningdek ulanish portini (sukut boʻyicha 8088) koʻrsatishingiz kerak.
  • Terminaldagi HTTPS rejimi faqat BioSecurity ushbu protokoldan foydalansa faollashtirilishi kerak.
    (HTTPS qo'llab-quvvatlash server boshqaruv konsolida sozlangan)
  • Yuqoridagi amallarni bajarganingizdan so'ng, qurilmani "Qidirish" orqali topish mumkin Qurilmalar ilovasida.
  • Kontrollerni BioSecurity dasturi oʻrnatilgan server bilan bir xil mahalliy tarmoqqa ulashingiz kerak (kontrolörlarda sukut boʻyicha IP 192.168.1.201 mavjud).
  • Bundan keyin kontrollerni “Qidiruv” orqali topish mumkin "Qurilmalar" ko'rinishida qo'shish tugmasini bosing va BioSecurity dasturi o'rnatilgan serverning IP manzilini hamda ulanish portini (sukut bo'yicha 8088) belgilang.
  • Kontrollerni qayta ishga tushirgandan so'ng, "Qurilmalar" sahifasini yangilashingiz kerak.

Yorliqga o'ting «Kirish», keyin ichkariga «Panel I/O» yon menyuda va bosing «Yaratmoq». Ochilgan oynada nom kiriting, boshqaruvchini tanlang - C2-260,  protokol turi - RS485, panel turi – DM10 va manzilingizni ko'rsating DM10.

BioSecurity – Bu elektron boshqaruv tizimining funksionalligi bilan veb-ga asoslangan kirishni boshqarish platformasi. BioSecurity - bu BioAccessning kengaytirilgan versiyasi. Dasturiy ta'minotning demo muddati 60 kun. Litsenziyani uskuna sotib olingan distribyutordan olish mumkin.

BioAccess yuklab olish havolasi: https://zkteco.bitrix24.ru/~Y3ZCm

BioAccess qoʻllanmasiga havola: https://zkteco.bitrix24.ru/~tFClO< / p>  

BioSecurity yuklab olish havolasi: https://zkteco.bitrix24.ru/~jINZF

BioSecurity qoʻllanmasiga havola: https://zkteco.bitrix24.ru/~ApMQv

Agar o'quvchi RS485 orqali kontrollerga ulangan bo'lsa, quyidagilarni tekshirishingiz kerak:

  • manzil WR485 konvertoridagi yoki orqa tarafdagi RS485 o'quvchining o'zida DIP kalitlari tomonidan o'rnatiladi;
  • oʻquvchi sozlamalarida shifrlash yoqilgan;
  • o'quvchi sozlamalarida ulanish turi (RS485 bo'lishi kerak);
  • tizimda shifrlash o'chirilgan -> Aloqa boshqaruvi -> Aloqa monitori (ba'zi dasturiy ta'minot versiyalarida);
  • o‘quvchining boshqaruvchiga ulanish diagrammasi.
 

Agar o'quvchi Wiegand orqali kontrollerga ulangan bo'lsa, quyidagilarni tekshirishingiz kerak:

  • o‘quvchi sozlamalarida shifrlash o‘chirilgan;
  • o'quvchi sozlamalarida ulanish turi (Wigand bo'lishi kerak);
  • tizimda shifrlash o'chirilgan -> Aloqa boshqaruvi -> Aloqa monitori (ba'zi dasturiy ta'minot versiyalarida);
  • o‘quvchining boshqaruvchiga ulanish diagrammasi.

Global ikki marta o'tish taqiqlanadi – O'tish ketma-ketligini boshqarish funktsiyasi, bu tashqi boshqaruv maydoniga kirmasdan ichki hududdan chiqishni oldini oladi va aksincha. Sozlash uchun sizga kerak:

  • Kirish sahifasida fon skanerlashni yoqish –> Qurilmalar –> Sozlash –> Fon tekshiruvi;
  • Kirish yorlig'idagi Kengaytirilgan funksiyalar bo'limida siz hudud va o'quvchi yo'nalishlarini yaratishingiz kerak;
  • Global ikki tomonlama o‘tish taqiqini sozlang.
  • Dastur sotuvchisidan seriya raqami faylini oling;
  • Dasturni ishga tushiring va litsenziyani boshqarish oynasini oching;
  • Ro‘yxatdan o‘tish formasi maydonlariga ma’lumotlaringizni kiriting;
  • "UPK-ni yuklab olish" tugmasini bosing va ochilgan oynada yetkazib beruvchidan olingan seriya raqami fayliga yo'lni belgilang;
  • Seriya raqami joylashgan papkada tizim avtomatik ravishda UPK_XX.xml formatida faollashtirish so‘rovi faylini yaratadi;
  • Yordam bo'limida zkteco.com portaliga o'ting –> Litsenziyani faollashtirish –> Tegishli dasturni tanlang yoki havolaga o'ting:

BioAccess/BioSecurity:

https://www.zkteco.com/en/active_upk.html?type=ZKBioSecurity%20License %20Activation

BioTA 8.0:

https://www.zkteco.com/en/active_upk.html?type=BioTime8.0%20Offline%20Activation%20License;

  • Seriya raqami fayli va UPK faylini portalga yuklang. "Yuklab olish" tugmasini bosing. Faollashtirish kalitini XX-License.XML fayl formatida oling;
  • Dastur oynasiga qaytish. "Oflayn faollashtirish" tugmasini bosing va ochilgan oynada zkteco.com portalida olingan faollashtirish kaliti fayliga yo'lni belgilang;
  • Ma'lumotlarni tekshirish tugashini kuting. Agar hamma narsa toʻgʻri koʻrsatilgan boʻlsa, “Roʻyxatdan oʻtish muvaffaqiyatli yakunlandi” bildirishnomasi bilan oyna paydo boʻladi.

*Belgilangan maydonlarni kiritish shart.

Terminaldagi menyu orqali yoki u qoʻshilgan dasturiy taʼminot orqali terminalni zavod sozlamalariga qaytarish mumkin.

Agar terminal bloklangan va dasturiy ta'minotga qo'shilmagan bo'lsa, uskunani sotib olgan distribyutor bilan bog'lanishingiz kerak.

Ha. Tashqi ishlov sifatida.

Quyidagi konfiguratsiyalar qo'llab-quvvatlanadi:

  • Ish haqi va xodimlarni boshqarish, 3-nashr, 3.1.11.108 va undan oldingi versiya;
  • Ish haqi va xodimlarni boshqarish CORP, 3-nashr;
  • 1C:ERP Enterprise Management, 2-nashr, 2.4.11.63 va undan oldingi versiyalari.

Boshqa konfiguratsiyalarda ishlash uchun konfiguratsiyangizda standart quyi tizim kutubxonasining eng soʻnggi versiyasi mavjudligiga ishonch hosil qiling.

ADMS – BioTA 8.0, BioAccess va BioSecurity veb platformalari bilan ishlash uchun zarur bo'lgan xizmat. Agar u mavjud boʻlsa, tarmoq sozlamalaridagi qurilma menyusida bulutli serverni sozlash bandi boʻlishi kerak, bu yerda serverning IP manzili va porti koʻrsatilgan.

Ushbu variantni qo'shish mumkin. Buning uchun uskunani sotib olgan distribyutorga murojaat qilishingiz kerak.

Ta'kidlash joizki, Wi-Fi tarmog'i va Ethernet tarmog'i turli quyi tarmoqlarga ega bo'lishi kerak.

Ushbu muammo jild yo'lida kirillcha belgilar mavjudligi sababli yuzaga keladi.

ZKTeco turniketlarining ichida boshqaruv platasi mavjud bo'lib, unda juft kontaktlar guruhlari (K1/GND, K2/GND) joylashgan bo'lib, yopilganda u yoki bu yo'nalishda o'tish joyi ochiladi. Tekshirish signalining davomiyligi 1 soniyadan oshmasligi kerak.

Kontrollerlar va terminallar blokirovkani boshqarish uchun kontaktlar guruhiga ega (NO, NC va COM), ular quyidagicha ishlaydi: kutish rejimida NC va COM yopiq, NO va COM ochiq, NC ochilganda va COM ochiq, NO va COM yopiq. Ochilish muddati dasturiy ta'minotdagi eshik sozlamalarida o'rnatiladi. Terminallarni to'g'ridan-to'g'ri kirishni boshqarish sozlamalaridagi menyu orqali ham sozlash mumkin, bu erda turniket rejimi taqdim etiladi, bu ochilish vaqtini 1 soniyagacha belgilaydi.

Savollaringiz bormi?

Siz so'rov qoldirishingiz mumkin, bizning mutaxassisimiz sizga qo'ng'iroq qiladi va ish soatlarida barcha savollarga javob beradi. Bizning ish jadvalimiz:
du-ju soat 9:00 dan 18:00 gacha, sh 9:00 dan 16:00 gacha

×